undefined
+
  • undefined

Temperature control device in FC2490 cooler

Sales Hotline:

After-sales Hotline:

Share to

  • Product Description
  • Overview

      The working principle of the FC2490 intercooler control device is as follows: High-temperature compressed air from the engine turbocharger outlet is cooled by heat exchange with the water flow outside the pipes inside the air cooler in the FC2490 intercooler control device. By controlling the flow rate of the cooling water, the temperature of the air after intercooling is controlled, achieving temperature regulation of the high-temperature gas.

     

    Technical Performance

    1. Temperature Measurement

    ① Measurement Range: 0~150℃

    ② Measurement Accuracy: ±1%F.S

    ③ Sensor Type: PT100

    ④ Display Resolution: 0.5℃

    2. Temperature Control

    ① Setpoint Accuracy: 0.5℃

    ② Steady-State Control Accuracy: ±2℃

    ③ Control Range: 40~80℃

    3. Technical Parameters

    ① Maximum Inlet Air Pressure: 0.3MPa

    ② Rated Airflow: 0.36kg/s

    ③ Cooling Water Inlet Temperature: 0~35℃

    ④ Compressed Air Pressure: 0.4~1Mpa

    ⑤ Dimensions: Length x Width x Height 800x350x1240(mm)

Product Inquiry